SRS DTC Troubleshooting: 11-1x, 11-4x

  1. Check resistance between the terminals of both SRS simulator leads. There should be 1 Ω or less.
Is the resistance as specified?
YES -
Faulty SRS unit or poor connection at SRS unit connector A (28P) and the SRS unit. Check the connection between the connector and the SRS unit. If the connection is OK, replace the SRS unit. ■
NO -
Open or increased resistance in the combination switch wire harness; replace the combination switch wire harness.■