M/T Shift Arm Clearance Inspection
Measure the clearance between the shift arm (A) and shift piece (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.26−0.57 mm (0.010−0.022 in.)
Service Limit:
0.75 mm (0.030 in.)