M/T Shift Arm Clearance Inspection

  1. Measure the clearance between the shift arm (A) and shift piece (B) with a feeler gauge (C). If the clearance is more than the service limit, go to Step 2 .
    Standard:
    0.26−0.57 mm (0.010−0.022 in.)
    Service Limit:
    0.75 mm (0.030 in.)