M/T Countershaft Assembly Clearance Inspection

  1. Measure the clearance between the 1st gear (A) and the distance collar (B) with a feeler gauge (C).
    • If the clearance is more than the service limit, go to Step 2 .
    • If the clearance is within the service limit, go to Step 4 .
    Standard:
    0.06−0.21 mm (0.002−0.008 in.)
    Service Limit:
    0.25 mm (0.010 in.)