M/T Mainshaft Inspection

  1. Inspect the gear and bearing contact areas for wear and damage, then measure the mainshaft at points A, B, C, D, and E. If any part of the mainshaft is less than the service limit, replace it.

    Standard:

    A Ball Bearing Surface (Transmission Housing   Side):
    24.987−25.000 mm (0.9837−0.9843 in.)
    B Distance Collar Surface:
    28.992−29.005 mm (1.1414−1.1419 in.)
    C Needle Bearing Surface:
    34.984−35.000 mm (1.3773−1.3780 in.)
    D Ball Bearing Surface (Clutch Housing Side):
    25.977−25.990 mm (1.0227−1.0232 in.)
    E Bushing Surface:
    14.870−14.890 mm (0.5854−0.5862 in.)
    Service Limit:
    A:
    24.93 mm (0.981 in.)
    B:
    28.93 mm (1.139 in.)
    C:
    34.93 mm (1.375 in.)
    D:
    25.92 mm (1.020 in.)
    E:
    14.77 mm (0.5815 in.)