M/T Countershaft Assembly Clearance Inspection
Measure the clearance between the 2nd gear (A) and 3rd gear (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 5
.
Standard:
0.06−0.14 mm (0.002−0.006 in.)
Service Limit:
0.23 mm (0.009 in.)