DLC Circuit Troubleshooting - PGM-FI System

  1. Check for continuity between ECM connector terminal A25 and body ground.
Is there continuity?
YES -
Go to Step 82 .
NO -
Go to Step 83 .
  1. Continue to check for continuity between ECM connector terminal A25 and body ground, while disconnecting the APP sensor 6P connector.
Is there continuity?
YES -
Repair short in the wire between the ECM (A25) and APP sensor B.■
NO -
Replace the accelerator pedal module. ■