DLC Circuit Troubleshooting - PGM-FI System

  1. Check for continuity between ECM connector terminal A3 and body ground.
Is there continuity?
YES -
Go to Step 31 .
NO -
Repair open in the wire between the ECM (A3) and DLC terminal No. 6.■