Power Relay Test

Radiator fan relay, Condenser fan relay, Blower motor relay
  1. Disconnect the under-hood fuse/relay box connector E (20P).
  1. At the under-hood fuse/relay box side, do the following test.
    Radiator fan relay:
    • Connect power to the No. 15, and ground to the No. 4 terminals. There should be battery voltage between the No. 11 terminal and the body ground.
    • Disconnect power from the No. 15, and ground from the No. 4 terminals. There should be no voltage between the No. 11 terminal and the body ground.
    Condenser fan relay:
    • Connect power to the No. 15, and ground to the No. 16 terminals. There should be battery voltage between the No. 13 terminal and the body ground.
    • Disconnect power from the No. 15, and the No. 16 terminals. There should be no voltage between the No. 13 terminal and the body ground.
    Blower motor relay:
    • Connect power to the No. 6, and ground to the No. 1 terminals. There should be battery voltage between the No. 3 terminal and the body ground.
    • Disconnect power from the No. 6, and ground from the No. 1 terminals. There should be no voltage between the No. 3 terminal and the body ground.