M/T Mainshaft Assembly Clearance Inspection

  1. Measure clearance between 6th gear (A) and the angular ball bearing (B) with a feeler gauge (C). If the clearance is more than the service limit, go to Step 11 .
    Standard:
    0.06−0.16 mm (0.002−0.006 in.)
    Service Limit:
    0.25 mm (0.010 in.)