M/T Mainshaft Assembly Clearance Inspection
Measure clearance between 6th gear (A) and the angular ball bearing (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 11
.
Standard:
0.06−0.16 mm (0.002−0.006 in.)
Service Limit:
0.25 mm (0.010 in.)