M/T Mainshaft Assembly Clearance Inspection
Measure clearance between the distance collar (A) and 5th gear (B) with a dial indicator (C). If the clearance is more than the service limit, go to
Step 8
.
Standard:
0.06−0.16 mm (0.002−0.006 in.)
Service Limit:
0.25 mm (0.010 in.)