Inspect the pressure plate (A) surface for wear, cracks, and burning.
-
Inspect for warpage using a straight edge (B) and a feeler gauge (C). Measure across the pressure plate. If the warpage is more than the service limit, replace the pressure plate.
|
Standard (New):
|
0.03 mm (0.001 in.) max.
|
|
Service Limit:
|
0.15 mm (0.006 in.)
|
|
|