Check the housing-to-outer rotor radial clearance between the outer rotor (A) and pump housing (B). If the housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump.
|
Housing-to-Outer Rotor Radial Clearance
|
|
Standard (New):
|
0.15−0.21 mm (0.006−0.008 in.)
|
|
Service Limit:
|
0.23 mm (0.009 in.)
|
-
Inspect both rotors and the pump housing for scoring or other damage. Replace parts if necessary.
|
|