Check the housing-to-rotor axial clearance between the rotor (A) and pump housing (B). If the housing-to-rotor axial clearance exceeds the service limit, replace the oil pump.
|
Housing-to-Rotor Axial Clearance
|
|
Standard (New):
|
0.035−0.070 mm (0.0014−0.0028 in.)
|
|
Service Limit:
|
0.12 mm (0.005 in.)
|
|
|