F-CAN Circuit Troubleshooting - PGM-FI System
Check for continuity between SRS unit connector A (28P) terminal No. 11 and body ground.
Is there continuity?
YES
-
Go to
Step 16
.
NO
-
Repair open in the wire between the ECM (A36) and the SRS unit.■
Remove the jumper wire from ECM connector A (44P).