F-CAN Circuit Troubleshooting - PGM-FI System
Check for continuity between gauge control module (tach) 36P connector terminal No. 1 and body ground.
Is there continuity?
YES
-
Go to
Step 13
.
NO
-
Repair open in the wire between the ECM (A36) and the gauge control module (tach).■