DTC Troubleshooting: B1229 (E)

  1. Check for continuity between the heater control unit 32P connector terminal No. 24 and the sunlight sensor 2P connector terminal No. 2.
Is there continuity?
YES -
Go to Step 10 .
NO -
Repair open in the wire between the heater control unit and the sunlight sensor.■
  1. Reconnect the sunlight sensor 2P connector.
  1. Reconnect the heater control unit 32P connector.
  1. Test the sunlight sensor.
Is the sunlight sensor OK?
YES -
Check for loose wires or poor connections at the heater control unit 32P connector and at the sunlight sensor 2P connector. If the connections are good, substitute a known-good heater control unit, and recheck. If the symptom/indication goes away, replace the original heater control unit .■
NO -
Replace the sunlight sensor. ■