M/T Mainshaft Assembly Clearance Inspection
Measure the clearance between the distance collar (A) and 5th gear (B) with a dial indicator (C). If the clearance is more than the service limit, go to
Step 8
.
Standard:
0.06−0.19 mm (0.002−0.007 in.)
Service Limit:
0.3 mm (0.01 in.)