M/T Reverse Shift Lever Clearance Inspection
Measure the clearance between the reverse shift lever (A) and reverse shift fork (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.05−0.50 mm (0.002−0.020 in.)
Service Limit:
0.6 mm (0.024 in.)