M/T Shift Fork Clearance Inspection
-
Measure the thickness of the shift fork fingers.
-
If the thickness is not within the standard, replace the shift fork.
-
If the thickness is within the standard, replace the synchro sleeve.
-
If one arm of the shift fork shows more wear than others, the fork may be bent and needs to be replaced.
Standard:
|
1st/2nd, 3rd/4th, 5th/6th:
|
7.4−7.6 mm (0.29−0.30 in.)
|
|
Reverse:
|
6.2−6.4 mm (0.24−0.25 in.)
|
|
|