M/T Shift Fork Clearance Inspection

  1. Measure the thickness of the shift fork fingers.
    • If the thickness is not within the standard, replace the shift fork.
    • If the thickness is within the standard, replace the synchro sleeve.
    • If one arm of the shift fork shows more wear than others, the fork may be bent and needs to be replaced.

    Standard:

    1st/2nd, 3rd/4th, 5th/6th:
    7.4−7.6 mm (0.29−0.30 in.)
    Reverse: