M/T Select Arm Clearance Inspection
Measure the clearance between the select arm (A) and interlock (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.05−0.25 mm (0.002−0.010 in.)
Service Limit:
0.5 mm (0.020 in.)