M/T Countershaft Assembly Clearance Inspection
Measure the clearance between 2nd gear (A) and 3rd gear (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 5
.
Standard:
0.04−0.17 mm (0.002−0.007 in.)
Service Limit:
0.28 mm (0.011 in.)