M/T Countershaft Assembly Clearance Inspection

  1. Measure the thickness of 1st gear.
    • If the thickness is less than the service limit, replace 1st gear.
    • If the thickness is within the service limit, replace the 1st/2nd synchro hub/sleeve.
    Standard:
    22.91−22.99 mm (0.902−0.905 in.)
    Service Limit: