Starter Overhaul

  1. Check the commutator diameter. If the diameter is below the service limit, replace the armature.

    Commutator Diameter

    Standard (New):
    31.9−32.1 mm (1.256−1.263 in.)
    Service Limit:
    31.4 mm (1.24 in.)