Engine Oil Pump Overhaul

  1. Check the housing-to-rotor axial clearance between the rotor (A) and lower balancer shaft holder (B). If the housing-to-rotor axial clearance exceeds the service limit, replace the oil pump.
    Housing-to-Rotor Axial Clearance
    Standard (New):
    0.020−0.055 mm
    (0.0008−0.0022 in.)
    Service Limit:
    0.1 mm (0.004 in.)