MIL Circuit Troubleshooting
Turn the ignition switch ON (II).
Do the gauge self-diagnostic function.
Does the MIL indicator flash?
YES
-
Go to
Step 3
.
NO
-
Substitute a known-good gauge control module (tach), and recheck. If the MIL circuit is OK,
replace the original gauge control module (tach).
■
Connect the HDS to the DLC.
Check the SCS in the DATA LIST with the HDS.
Is a short indicated?
YES
-
Go to
Step 5
.
NO
-
Update the ECM if it does not have the latest software,
or
substitute a known-good ECM,
then recheck. If the symptom/indication goes away with a known-good ECM,
replace the original ECM.
■
Turn the ignition switch OFF, and wait 2 minutes.
Disconnect the HDS from the DLC.
Check for continuity between ECM connector No. 2 terminal No. 20 and body ground.
Is there continuity?
YES
-
Repair short in the wire between the SRS unit, the DLC and ECM connector No. 2 terminal No. 20.■
NO
-
Update the ECM if it does not have the latest software,
or
substitute a known-good ECM,
then recheck. If the symptom/indication goes away with a known-good ECM,
replace the original ECM.
■