F-CAN Circuit Troubleshooting

  1. Measure resistance between ECM connector No. 2 terminals No. 47 and No. 48.
Is there about 2.34−2.86 KΩ?
YES -
Go to Step 32 .
NO -
Substitute a known-good SRS unit. If the HDS communicate with the ECM, replace the original SRS unit. ■
  1. Disconnect SRS unit connector A (28P).
  1. Reconnect EPS control unit connector D (28P).