DLC Circuit Troubleshooting

  1. Check for continuity between ECM connector No. 2 terminal No. 47 and DLC terminal No. 6.
Is there continuity?
YES -
Go to Step 29 .
NO -
Repair open in the wire between DLC terminal No. 6 and ECM connector No. 2 terminal No. 47.■