DLC Circuit Troubleshooting
Check for continuity between ECM connector No. 2 terminal No. 47 and DLC terminal No. 6.
Is there continuity?
YES
-
Go to
Step 29
.
NO
-
Repair open in the wire between DLC terminal No. 6 and ECM connector No. 2 terminal No. 47.■