Remove the upper camshaft holders. Measure the widest part of plastigage on each journal.
|
Camshaft-to-Holder Oil Clearance
|
|
Standard (New):
|
|
|
No. 1 Journal:
|
0.0012−0.0027 mm (0.00005−0.00011 in.)
|
|
No. 2, 3, 4, 5 Journals:
|
0.0020−0.0035 mm (0.00008−0.00014 in.)
|
|
Service Limit:
|
|
|
No. 1 Journal:
|
0.08 mm (0.003 in.)
|
|
No. 2, 3, 4, 5 Journals:
|
0.10 mm (0.004 in.)
|
|
|