Alternator Control Circuit Troubleshooting
Check for continuity between ECM connector No. 1 terminal No. 80 and alternator 4P connector terminal No. 2.
Is there continuity?
YES
-
Replace the alternator,
or
repair the alternator.
■
NO
-
Repair open in the wire between the alternator and ECM.■