M/T Reverse Lockout System Circuit Troubleshooting
At reverse lockout solenoid side, connect the No. 2 terminal of the reverse lockout solenoid to the battery positive terminal, and connect the No. 1 terminal to the battery negative terminal. Check that the reverse lockout solenoid operates.
Does the reverse lockout solenoid operate properly?
YES
-
If necessary, update the ECM if it does not have the latest software, or
substitute a known-good ECM, then recheck.
If the symptom/indication goes away with a known-good ECM, replace the original
ECM
.■