M/T Shift Fork Clearance Inspection

  1. Measure the thickness of the shift fork fingers.
    • If the thickness is not within the standard, replace the shift fork.
    • If the thickness is within the standard, replace the synchro sleeve.
    Standard:
    1st/2nd shift fork:
    6.7−6.9 mm (0.26−0.27 in.)
    3rd/4th, 5th/6th shift fork:
    7.4−7.6 mm (0.29−0.30 in.)