M/T Mainshaft Assembly Clearance Inspection
Measure the thickness of 5th gear.
If the thickness is less than the service limit, replace 5th gear.
If the thickness is within the service limit, replace the 5th synchro hub.
Standard:
22.42−22.47 mm (0.883−0.885 in.)
Service Limit:
22.35 mm (0.880 in.)