M/T Mainshaft Assembly Clearance Inspection
Measure the thickness of 3rd gear.
If the thickness is less than the service limit, replace 3rd gear.
If the thickness is within the service limit, replace the 3rd/4th synchro hub.
Standard:
27.02−27.07 mm (1.064−1.066 in.)
Service Limit: