M/T Shift Arm Clearance Inspection

  1. Measure the clearance between the shift arm (A) and shift piece (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to Step 2 .
    Standard:
    0.20−0.61 mm (0.008−0.024 in.)
    Service Limit:
    0.7 mm (0.028 in.)