M/T Countershaft Assembly Clearance Inspection

  1. Measure the thickness of the distance collar.
    • If the thickness is not within the standard, replace the distance collar with a new one.
    • If the thickness is within the standard, go to Step 6 .
    Standard:
    26.53−26.56 mm (1.044−1.046 in.)