M/T Countershaft Assembly Clearance Inspection

  1. Measure the thickness of the distance collar.
    • If the thickness is not within than the standard, replace the distance collar with a new one.
    • If the thickness is within the standard, go to Step 3 .
    Standard:
    21.53−21.58 mm (0.843−0.849 in.)