F-CAN Circuit Troubleshooting - PGM-FI System
Measure resistance between ECM connector terminals A36 and A37.
Is there about 2.34−2.86 kΩ?
YES
-
Go to
Step 36
.
NO
-
Substitute a known-good EPS control unit.
If the HDS communicate with the ECM,
replace the original EPS control unit.
■
Disconnect EPS control unit connector D (28P).
Reconnect SRS unit connector A (28P).