SRS DTC Troubleshooting: 11-1x
Check resistance between the terminals of the black SRS simulator lead (A). There should be 1 Ω or less.
Is the resistance as specified?
YES
-
Faulty SRS unit or poor connection at SRS unit connector A (28P). Check the connection; if the connection is OK,
replace the SRS unit.
■
NO
-
Open or increased resistance in the combination switch wire harness; replace the combination switch wire harness.■