SRS DTC Troubleshooting: 12-8x

  1. Check for voltage between each terminal of the black SRS simulator lead (A) and body ground. There should be 0.5 V or less.
Is the voltage as specified?
YES -
Faulty SRS unit or poor connection at SRS unit connector A (28P) and the SRS unit. Check the connection between the connector and the SRS unit. If the connection is OK, replace the SRS unit. ■
NO -
Short to power in the combination switch wire harness; replace the combination switch wire harness.■