SRS DTC Troubleshooting: 44-1x

  1. Check for voltage between the No. 27 terminal of SRS unit connector B (28P) and body ground, and between the No. 28 terminal and body ground. There should be 1 V or less.
Is the voltage as specified?
YES -
Go to Step 16 .
NO -
Short to power in the floor wire harness; replace the floor wire harness.■
  1. Turn the ignition switch OFF.