Check resistance between the terminals of the black SRS simulator lead (A). There should be an open circuit or at least 1 MΩ.
Is the resistance as specified?
YES
-
Faulty SRS unit or poor connection at SRS unit connector B (28P) and the SRS unit. Check the connection; if the connection is OK,
replace the SRS unit.
■
NO
-
Short to another wire in the floor wire harness; replace the floor wire harness.■