EPS DTC Troubleshooting: 33-01, 33-06

  1. Check for continuity between body ground and the EPS control unit connector B (2P) No. 1 terminal, connector C (2P) No. 1 terminal, connector C (2P) No. 2 terminal individually.
Is there continuity?
YES -
Repair short in the wire harness between the EPS control unit and motor.■
NO -
Short in the motor wire harness, or motor internal circuit, replace the motor. ■