Check for continuity between body ground and the EPS control unit connector B (2P) No. 1 terminal, connector C (2P) No. 1 terminal, connector C (2P) No. 2 terminal individually.
Is there continuity?
YES
-
Repair short in the wire harness between the EPS control unit and motor.■
NO
-
Short in the motor wire harness, or motor internal circuit,
replace the motor.
■