Door Key Cylinder Switch Test

  1. Remove the driver's door panel.
  1. Disconnect the 10P connector from the door lock actuator.
  1. Check for continuity between the terminals.
    • There should be continuity between the No. 8 [No. 7] and No. 5 [No. 10] terminals when the door key cylinder switch is in UNLOCK position.
    • There should be no continuity between the No. 8 [No. 7] and No. 5 [No. 10] terminals when the door key cylinder switch is in the neutral or LOCK position.
    • There should be continuity between the No. 9 [No. 6] and No. 5 [No. 10] terminals when the door key cylinder switch is in UNLOCK position.
    • There should be no continuity between the No. 9 [No. 6] and No. 5 [No. 10] terminals when the door key cylinder switch is in the neutral or LOCK position.
    [ ]:
    RHD type

  1. If the continuity is not as specified, replace the door lock actuator.