Security Alarm Control Siren Input Test
-
-
Disconnect the 4P connector (A) from the alarm control siren (B).
|
|
|
-
Inspect the connector and socket terminals to be sure they are all making good contact.
-
Make these input tests at the connector.
-
If any test indicates a problem, find and correct the cause, then recheck the system.
-
If all the input tests prove OK, replace the alarm control siren.
|
Cavity
|
Wire
|
Test condition
|
Test: Desired result
|
Possible cause if result is not obtained
|
|
1
|
BLK
|
Under all conditions
|
Check for continuity to ground:
There should be continuity.
|
-
Poor ground (G652)
-
An open in the wire
|
|
2
|
GRN
|
Under all conditions
|
Check for continuity between the No. 2 terminal and No. 2 terminal of the ultrasonic sensor: There should be continuity.
|
An open in the wire
|
|
3
|
YEL
|
Under all conditions
|
Check for continuity between the No. 3 terminal and T15 terminal of the MICU: There should be continuity.
|
An open in the wire
|
|
4
|
WHT
|
Under all conditions
|
Check for voltage to ground: There should be battery voltage.
|
|
|