Keyless/Power Door Locks/Security Alarm System Symptom Troubleshooting - Keyless operation does not work (LOCK, UNLOCK)

  1. Check for continuity between the immobilizer-keyless control unit 7P connector No. 6 terminal and body ground.
Is there continuity?
YES -
Repair a short to ground in the wire.■
NO -
Replace the immobilizer-keyless control unit.■