DTC P0522:
EOP Sensor Circuit Low Voltage
-
Turn the ignition switch ON (II).
-
Check the EOP SENSOR in the DATA LIST with the HDS.
|
Is there about 0.18 V or less?
|
|
YES
|
-
|
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the EOP sensor and the ECM.■
|
-
Turn the ignition switch OFF.
-
Disconnect the EOP sensor 3P connector.
-
Turn the ignition switch ON (II).
-
Check the EOP SENSOR in the DATA LIST with the HDS.
|
Is there about 0.18 V or less?
|
-
Measure voltage between EOP sensor 3P connector terminals No. 1 and No. 3.
-
Turn the ignition switch OFF.
-
Jump the SCS line with the HDS.
-
Disconnect ECM connector C (44P).
|