DTC P19EF:
Shift Actuator Motor Position Sensor Ground Line Open
-
Turn the ignition switch to ON (II).
-
Clear the DTCs with the HDS.
-
Turn the ignition switch to LOCK (0).
-
Turn the ignition switch to ON (II).
-
Check for DTCs with the HDS.
|
YES
|
-
|
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time.■
|
-
Turn the ignition switch to LOCK (0).
-
Disconnect the shift actuator motor 6P connector.
-
Disconnect the change actuator subharness B 8P connector (R18A2 engine model) or TCM connector B (40P) (L13Z1 engine model).
-
Check for continuity between change actuator subharness B 8P connector terminal No. 4 (R18A2 engine model) or TCM connector B1 (L13Z1 engine model) and shift actuator motor 6P connector terminal No. 2.
|
YES
|
-
|
|
|
NO
|
-
|
Repair an open in the wire of change actuator subharness B (R18A2 engine model) or change actuator subharness A (L13Z1 engine model).■
|
|