Measure clearance between 1st gear (A) and the distance collar (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 2
.
Standard:
0.06−0.16 mm (0.002−0.006 in.)
Service Limit:
0.25 mm (0.010 in.)
Measure length of the distance collar as shown.
If the length is not within the standard, replace the distance collar.
If the length is within the standard, go to
Step 3
.
Standard:
23.03−23.08 mm (0.907−0.909 in.)
Measure thickness of 1st gear.
If the thickness is less than the service limit, replace 1st gear.
If the thickness is within the service limit, replace the 1st/2nd synchro hub and reverse gear as a set.
Standard:
22.92−22.97 mm (0.902−0.904 in.)
Service Limit:
22.87 mm (0.900 in.)
Measure clearance between 2nd gear (A) and 3rd gear (B) with a feeler gauge (C). If the clearance is more than the service limit, go to
Step 5
.
Standard:
0.06−0.16 mm (0.002−0.006 in.)
Service Limit:
0.25 mm (0.010 in.)
Measure length of the distance collar.
If the length is not within the standard, replace the distance collar.
If the length is within the standard, go to
Step 6
.
Standard:
28.03−28.08 mm (1.104−1.106 in.)
Measure thickness of 2nd gear.
If the thickness is less than the service limit, replace 2nd gear.
If the thickness is within the service limit, replace the 1st/2nd synchro hub and reverse gear as a set.