MIL Circuit Troubleshooting - PGM-FI System

  1. Turn the ignition switch ON (II).
Does the MIL indicator flash?
YES -
Go to Step 3 .
NO -
  1. Check the SCS in the DATA LIST with the HDS.
Is a short indicated?
YES -
Go to Step 5 .
NO -
Update the ECM if it does not have the latest software, or substitute a known-good ECM, then recheck. If the symptom/indication goes away with a known-good ECM, replace the original ECM.
  1. Turn the ignition switch OFF.
  1. Disconnect ECM connector A (44P), then disconnect the HDS.
  1. Check for continuity between ECM connector terminal A31 and body ground.
Is there continuity?
YES -
Repair short in the wire between the ECM (A31) and the SRS unit, the DLC.■
NO -