DTC P0383:
Glow Plug Control Module Circuit Shorted to Ground
-
Turn the ignition switch ON (II).
-
Clear the DTC with the HDS.
-
Do the GLOW ON/OFF in the INSPECTION MENU with the HDS.
-
Check for Temporary DTCs or DTCs with the HDS.
|
YES
|
-
|
|
|
NO
|
-
|
Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the glow plug control module and the ECM.■
|
-
Turn the ignition switch OFF, and wait 2 minutes.
-
Disconnect the glow plug control module 11P connector.
-
Check for continuity between glow plug control module 11P connector terminal No. 11 and body ground.
-
Disconnect ECM connector No. 2 (58P).
|